35 research outputs found

    A Complete Analysis for Pump Controlled Single Rod Actuators

    Get PDF
    In the current study a variable speed pump controlled hydrostatic circuit where an underlapped shuttle valve is utilized to compensate the unequal flow rate of a single rod actuator is analyzed. Parameters of the shuttle valve are included in the system analysis, rather than treating it as an ideal switching element as handled in literature. A linearized model of the system is obtained. An inverse kinematic model, which calculates the required pump drive speed for a desired actuator speed and given pilot pressure input, is formed. A numerical stability analysis program is developed, and the stability of all possible shuttle valve spool positons is determined. The theoretical findings are validated by non-linear simulation model responses

    The role of stationary intraoral tomosynthesis in reducing proximal overlap in bitewing radiography

    Get PDF
    objectives: This study examined the utility of stationary intraoral tomosynthesis (s-IOT) in opening proximal contacts in bitewing radiography. Methods: 11 DENTSPLY Rinn Dental X-ray Teaching and Training Replica mannequins (Model #546002, Elgin, Ill) were imaged with a prototype s-IOT device (Surround Medical Systems, Morrisville, NC) and standard bitewing (SBW) technique. Premolar and molar bite-wings were acquired with each system. Image receptor holders were used to position receptors and aid in the alignment of the position indicating devices. An expert operator (having more than 5 years of experience in intraoral radiography) acquired the images with the s-IOT prototype and standard intraoral X-ray devices. Images were assessed to analyze percentage overlap of the proximal surfaces using the tools available in ImageJ (NIH, Bethesda Maryland). Results: 253-paired surfaces were included in the analysis. The difference in overlap was statistically significant with standard bitewing (SBW) images resulting in a median overlap of 13%, a minimum of 0%, a maximum of 100% and an interquartile range of 40%. s-IOT resulted in a median overlap of 1%, a minimum of 0%, a maximum of 37% and an interquartile range of 0%. The s-IOT prototype substantially reduced proximal surface overlap compared to conventional bitewing radiography. conclusions: The use of s-IOT reduced proximal contact overlap compared to standard bitewing radiography for an experienced radiographer. Stationary intraoral tomosynthesis may be a potential alternative to SBW radiography, reducing the number of retakes due to closed contacts

    Stationary intraoral digital tomosynthesis using a carbon nanotube X-ray source array

    Get PDF
    Intraoral dental tomosynthesis and closely related tuned-aperture CT (TACT) are low-dose three-dimensional (3D) imaging modalities that have shown improved detection of multiple dental diseases. Clinical interest in implementing these technologies waned owing to their time-consuming nature. Recently developed carbon nanotube (CNT) X-ray sources allow rapid multi-image acquisition without mechanical motion, making tomosynthesis a clinically viable technique. The objective of this investigation was to evaluate the feasibility of and produce high-quality images from a digital tomosynthesis system employing CNT X-ray technology

    Use of complementary and alternative medicine in cancer patients: a European survey

    Get PDF
    Background: The aim of this study was to explore the use of complementary and alternative medicine (CAM) in cancer patients across a number of European countries. Methods: A descriptive survey design was developed. Fourteen countries participated in the study and data was collected through a descriptive questionnaire from 956 patients. Results: Data suggest that CAM is popular among cancer patients with 35.9% using some form of CAM (range among countries 14.8% to 73.1%). A heterogeneous group of 58 therapies were identified as being used. Herbal medicines and remedies were the most commonly used CAM therapies, together with homeopathy, vitamins/minerals, medicinal teas, spiritual therapies and relaxation techniques. Herbal medicine use tripled from use before diagnosis to use since diagnosis with cancer. Multivariate analysis suggested that the profile of the CAM user was that of younger people, female and with higher educational level. The source of information was mainly from friends/family and the media, while physicians and nurses played a small part in providing CAM-related information. The majority used CAM to increase the body's ability to fight cancer or improve physical and emotional well-being, and many seemed to have benefited from using CAM (even though the benefits were not necessarily related to the initial reason for using CAM). Some 4.4% of patients, however, reported side-effects, mostly transient. Conclusions: It is imperative that health professionals explore the use of CAM with their cancer patients, educate them about potentially beneficial therapies in light of the limited available evidence of effectiveness, and work towards an integrated model of health-care provisio

    Characterization and preliminary imaging evaluation of a clinical prototype stationary intraoral tomosynthesis system

    Get PDF
    Purpose: Technological advancements in dental radiography have improved oral care on many fronts, yet diagnostic efficacy for some of the most common oral conditions, such as caries, dental cracks and fractures, and periodontal disease, remains relatively low. Driven by the clinical need for a better diagnostic yield for these and other dental conditions, we initiated the development of a stationary intraoral tomosynthesis (s-IOT) imaging system using carbon nanotube (CNT) x-ray source array technology. Here, we report the system characterization and preliminary imaging evaluation of a clinical prototype s-IOT system approved for human use. Methods: The clinical prototype s-IOT system is comprised of a multibeam CNT x-ray source array, high voltage generator, control electronics, collimator cone, and dynamic digital intraoral detector. During a tomosynthesis scan, each x-ray source is operated sequentially at fixed, nominal tube current of 7 mA and user-specified pulse width. Images are acquired by a digital intraoral detector and the reconstruction algorithm generates slice information in real time for operator review. In this study, the s-IOT system was characterized for tube output, dosimetry, and spatial resolution. Manufacturer specifications were validated, such as tube current, kVp, and pulse width. Tube current was measured with an oscilloscope on the analog output of the anode power supply. Pulse width, kVp, and peak skin dose were measured with a dosimeter with ion chamber and high voltage accessory. In-plane spatial resolution was evaluated via measurement of MTF and imaging of a line pair phantom. Spatial resolution in the depth direction was evaluated via artifact spread measurement. The size of the collimated radiation field was evaluated for compliance with FDA regulations. A dental phantom and human specimens of varying pathologies were imaged on a clinical 2D intraoral imaging system as well as s-IOT for comparison and to explore potential clinical applications. Results: The measured tube current, kVp, and pulse width values were within 3% of the set values. A cumulative peak skin dose of 1.12 mGy was measured for one complete tomosynthesis scan using a 50-ms pulse per projection view. Projection images and reconstruction slices revealed MTF values ranging from 8.1 to 9.3 cycles/mm. Line pair imaging verified this result. The radiation field was found to meet the FDA requirements for intraoral imaging devices. Tomosynthesis reconstruction slice images of the dental phantom and human specimens provided depth resolution, allowing visibility of anatomical features that cannot be seen in the 2D intraoral images. Conclusions: The clinical prototype s-IOT device was evaluated and found to meet all manufacturer specifications. Though the system capability is higher, initial investigations are targeting a low-dose range comparable to a single 2D radiograph. Preliminary studies indicated that s-IOT provides increased image quality and feature conspicuity at a dose comparable to a single 2D intraoral radiograph

    Applying synthetic radiography to intraoral tomosynthesis: A step towards achieving 3D imaging in the dental clinic

    Get PDF
    objectives: A practical approach to three-dimensional (3D) intraoral imaging would have many potential applications in clinical dentistry. Stationary intraoral tomosynthesis (sIOT) is an experimental 3D imaging technology that holds promise. The purpose of this study was to explore synthetic radiography as a tool to improve the clinical utility of the images generated by an sIOT scan. Methods: Extracted tooth specimens containing either caries adjacent to restorations (CAR) or vertical root fractures (VRF) were imaged by sIOT and standard dental radiography devices. Qualitative assessments were used to compare the conspicuity of these pathologies in the standard radiographs and in a set of multi-view synthetic radiographs generated from the information collected by sIOT. Results: The sIOT-based synthetic 2D radiographs contained less artefact than the image slices in the reconstructed 3D stack, which is the conventional approach to displaying information from a tomosynthesis scan. As a single sIOT scan can be used to generate synthetic radiographs from multiple viewing angles, the interproximal space was less likely to be obscured in the synthetic images compared to the standard radiograph. Additionally, the multi-view synthetic radiographs can potentially improve the display of CAR and VRFs as compared to a single standard radiograph. conclusions: This preliminary experience combining synthetic radiography and sIOT in extracted tooth models is encouraging and supports the ongoing study of this promising approach to 3D intraoral imaging with many potential applications

    Application of Multivariate Adaptive Regression Splines to Sheet Metal Bending Process for Springback Compensation

    No full text
    An intelligent regression technique is applied for sheet metal bending processes to improve bending performance. This study is a part of another extensive study, automated sheet bending assistance for press brakes. Data related to material properties of sheet metal is collected in an online manner and fed to an intelligent system for determining the most accurate punch displacement without any offline iteration or calibration. The overall system aims to reduce the production time while increasing the performance of press brakes

    A Complete Analysis for Pump Controlled Single Rod Actuators

    Get PDF
    In the current study a variable speed pump controlled hydrostatic circuit where an underlapped shuttle valve is utilized to compensate the unequal flow rate of a single rod actuator is analyzed. Parameters of the shuttle valve are included in the system analysis, rather than treating it as an ideal switching element as handled in literature. A linearized model of the system is obtained. An inverse kinematic model, which calculates the required pump drive speed for a desired actuator speed and given pilot pressure input, is formed. A numerical stability analysis program is developed, and the stability of all possible shuttle valve spool positons is determined. The theoretical findings are validated by non-linear simulation model responses

    Application of Multivariate Adaptive Regression Splines to Sheet Metal Bending Process for Springback Compensation

    No full text
    An intelligent regression technique is applied for sheet metal bending processes to improve bending performance. This study is a part of another extensive study, automated sheet bending assistance for press brakes. Data related to material properties of sheet metal is collected in an online manner and fed to an intelligent system for determining the most accurate punch displacement without any offline iteration or calibration. The overall system aims to reduce the production time while increasing the performance of press brakes
    corecore